Issue |
Radioprotection
Volume 38, Number 4, October-December 2003
|
|
---|---|---|
Page(s) | 493 - 508 | |
DOI | https://doi.org/10.1051/radiopro:2003015 | |
Published online | 17 June 2005 |
Évaluation du facteur de mise en suspension de contamination dans les installations nucléaires
Evaluation of the resuspension factor in nuclear power installations
1
IRSN, DPEA/SERAC, bâtiment 389, B.P. 68, 91192 Gif-sur-Yvette Cedex, France.
2
Service de protection radiologique des armées, 1 bis rue du lieutenant Raoul Batany, 92141 Clamart, France.
3
CEA, DAM, B.P. 12, 91680 Bruyères-le-Châtel, France.
4
Laboratoire de Radiochimie, Université de Liège, bâtiment B16, Sart-Tilman, 40000 Liège, Belgique.
5
Institut de Recherches Subatomiques, 23 rue de Lœss, B.P. 28, 67037 Strasbourg Cedex 2, France.
$^*$ Auteur pour la correspondance.
Reçu :
15
Novembre
2002
Accepté :
28
Mai
2003
Ce travail entre dans le cadre du dossier “maîtrise du risque alpha sur des
installations nucléaires” qui est issu du projet propreté radiologique d'EDF. Une
validation du facteur réaliste de mise en suspension de contamination est nécessaire
afin de s'assurer que les dispositions prises par EDF dans le cadre de la
radioprotection des travailleurs lors des interventions sur des chantiers à risque
alpha sont adaptées. Une expérimentation du facteur de mise en suspension sur
l'arrêt de tranche 3 de la centrale nucléaire Cattenom, qui a subit une dissémination
de matière fissile pendant l'arrêt de tranche en janvier 2001 a été réalisée. Le bilan
des activités surfaciques et atmosphériques sur trois types de chantiers
(pressuriseur, générateur de vapeur et piscine du bâtiment réacteur) est analysé.
L'ensemble des valeurs obtenues permet de fixer et d'adopter en radioprotection
opérationnelle la valeur la plus probable du facteur de mise en suspension des
particules émettrices α F m-1.
Abstract
Evaluation of the resuspension factor in nuclear power installations. This work is part of the EDF project “control of α-particle radiation risk in nuclear power stations”. A realistic determination of the resuspension factor of
contamination is necessary to be certain that the health protection measures taken
by the EDF for their on-site workers are applicable. An experimental determination
of the resuspension factor during the programmed maintenance of Unit 3 of the
Cattenom power station, which suffered a dispersion of fissile material during a
stoppage in January 2001, has been performed. The values of the surface and
atmospheric activity concentrations at three workspace (pressure unit, steam
generator and pool of the reactor building) are analysed. The results allow setting the
most realistic value of the resuspension factor for α-particle for operational
radiation protection at F m-1.
Key words: alpha particles / nuclear power plant / contamination / aerosols / exposure, personnel
© EDP Sciences, 2003
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.