Accès gratuit

Table 1

Experimental activities measured with the LaBr3(Ce) detector mounted on the drone at various heights and for different measurement times.

Distance source — detector Acquisition time Photopeak Gross area ± uncertainty Efficiency Activity ± uncertainty Detection Limit Relative difference
(m) (s) (energy keV)   (x10–5) (MBq) (MBq) (measure/reference) (%)
    137Cs (661.7) 2830 ±130 4.96 1.1 ± 0.1 0.12 –99
1 60 60Co (1173) 3200 ± 100 3.31      
    60Co (1332) 3110 ± 70 3.02 1.6 ± 0.2 0.08 –98
    137Cs (661.7) 920 ± 70 0.0967 19 ± 3 3.6 –75
2 60 60Co (1173) 1170 ± 60 0.0648      
    60Co (1332) 1210 ± 50 0.0593 32 ± 4 2.5 –60
    137Cs (661.7) 2420 ± 120 0.0239 40 ± 5 4.7 –47
4 300 60Co (1173) 3100 ± 100 0.0161      
    60Co (1332) 3160 ± 70 0.0147 68 ± 8 3.6 –15
    137Cs (661.7) 580 ± 60 0.0036 64 ± 10 17 –15
10 300 60Co (1173) 690 ± 40 0.0025      
    60Co (1332) 590 ± 40 0.0023 91 ± 12 16 13