Free Access
Issue |
Radioprotection
Volume 41, Number 4, October-December 2006
|
|
---|---|---|
Page(s) | 421 - 429 | |
DOI | https://doi.org/10.1051/radiopro:2006016 | |
Published online | 14 December 2006 |
- Allen P.D., Chaudhri M.A. (1988) Photoneutron production and dosimetry in tissue during high energy bremsstrahlung radiotherapy, Rad. Prot. Dos. 23, 341-344. [Google Scholar]
- Bartlett D.T., McAulay I.R., Schrewe U.J., Schnuer K., Menzel H.G., Bottollier-Depois J.-F., Dietze G., Gmür K., Grillmaier R.E., Heinrich W., Lim T., Lindborg L., Reitz G., Schraube H., Spurný F., Tommasino L. (1997) Dosimetry for occupational exposure to cosmic radiation, Rad. Prot. Dos. 70, 395-404. [Google Scholar]
- Charvát J. (1986) LET spectrometry with polymer SSNTD’s, Ph.D. thesis, University of Prague, 1986. [Google Scholar]
- Chibani O., Ma C.-M.C. (2003) Photonuclear dose calculations for high-energy photon beams from Siemens and Varian linacs, Med. Phys. 30, 1900-2000. [Google Scholar]
- IAEA (1987) Absorbed dose determination in photon and electron beams: an International Code of Practice, IAEA Technical Reports Series 277, IAEA, Vienna. [Google Scholar]
- ICRP Publication 60 (1991) 1990 Recommendations of the Internal Commission on Radiological Protection. Oxford, Pergamon Press. [Google Scholar]
- Schraube H., Leuthold G., Heinrich W., Roessler S., Mareš V., Schraube G. (1992) European program package for the calculation of aviation route doses – User’s manual, GSF-National Research Center on Environmental and Health. [Google Scholar]
- Spurný F., Bednár J., Johansson L., Sätherberg A. (1996a) LET spectra of secondary particles in CR 39 track etch detectors, Radiat. Meas. 26, 645-649. [CrossRef] [Google Scholar]
- Spurný F., Johansson L., Sätherberg A., Bednáø J., Turek K. (1996b) The contribution of secondary heavy particles to the absorbed dose from high-energy photon beams, Phys. Med. Biol. 41, 2643-2656. [CrossRef] [PubMed] [Google Scholar]
- Spurný F., Dachev Ts. (2003) Long-term monitoring of the onboard aircraft exposure level with a Si-diode based spectrometer, Adv. Space Res. 32, 53-58. [CrossRef] [PubMed] [Google Scholar]
- Spurný F., Molokanov A.G., Bamblevski V.P. (2004) Spectrometry of linear energy transfer, its development and use, Rad. Prot. Dos. 110, 675-679. [Google Scholar]
- Spurný F., Jadrnícková I., Molokanov A.G., Bamblevski V.P. (2005) Upgrading of LET track-etch spectrometer: Calibration and uncertainty analysis, Radiat. Meas. 40, 343-346. [CrossRef] [Google Scholar]
- Turek K., Spurný F., Alberts W.G. (1993) On the optimization of the etching of CR39 as fast neutron dosimeter, Nucl. Tracks Radiat. Measur. 21, 299-302. [Google Scholar]
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.