Table 3
Comparison of dose reduction due to bismuth shielding between the current study and other relevant studies.
Study | Shield composition | Measurement tools | Dose reduction (%) |
---|---|---|---|
Current Study | 100% Bi | TLD | 51.69 |
Hopper et al. (2002) | 100% Bi | – | 52.40 |
Yilmaz et al. (2007) | 100% Bi | TLD | 40.53 |
Catuzzo et al. (2010) | 100% Bi | TLD | 38.00 |
Huggett et al. (2013) | 100% Bi | MOSFET* | 50.00 |
Mendes et al. (2015) | 100% Bi | Ionization Chamber | 45.00 |
Vollmar et al. (2008) | 100% Bi | Monte Carlo Simulation | 42.80 |
Mehnati et al. (2018) | Bismuth-silicon | TLD | 57.90 |
& Bismuth-polyurethane | 37.60 |