Open Access
Issue |
Radioprotection
Volume 59, Number 4, October - December 2024
|
|
---|---|---|
Page(s) | 278 - 286 | |
DOI | https://doi.org/10.1051/radiopro/2024025 | |
Published online | 13 December 2024 |
- AAPM Report. 2024. The American Association of Physicists in Medicine (AAPM), AAPM position statement on the use of bismuth shielding for the purpose of dose reduction in CT scanning. Available from: https://www.aapm.org/org/policies/details.asp?type=PP&id=3590 [Last accessed on 17 April 2024]. [Google Scholar]
- Abolhadi S, Parach AA, Mehdipour A, Mehnati P, Sayadi AR. 2023. Evaluation of silicon and 10% bismuth shield with variable thickness compared with constant thickness on the dose reduction and image quality during chest CT examination. Radioprotection 58: 55–60. [CrossRef] [EDP Sciences] [Google Scholar]
- Akhlaghi P, Miri-Hakimabad H, Rafat-Motavalli L. 2014. Effects of shielding the radiosensitive superficial organs of ORNL pediatric phantoms on dose reduction in computed tomography. J Med Phys 39: 238–246. [CrossRef] [PubMed] [Google Scholar]
- Alonso TC, Mourão AP, Santana PC, da Silva TA. 2016. Assessment of breast absorbed doses during thoracic computed tomography scan to evaluate the effectiveness of bismuth shielding. Appl Radiat Isot 117: 55–57. [CrossRef] [PubMed] [Google Scholar]
- Bertho J-M., Bourguignon M. 2024. Un enjeu majeur de radioprotection en imagerie médicale. Radioprotection 59: 1–2. [CrossRef] [EDP Sciences] [Google Scholar]
- Catuzzo P, Aimonetto S, Fanelli G, Marchisio P, Meloni T, Mistretta L, ... Tofani S. 2010. Dose reduction in multislice CT by means of bismuth shields: results of in vivo measurements and computed evaluation. Radiol Med 115: 152–169. [CrossRef] [PubMed] [Google Scholar]
- Colletti PM, Micheli OA, Lee KH. 2013. To shield or not to shield: application of bismuth breast shields. AJR Am J Roentgenol 200: 503–507. [CrossRef] [PubMed] [Google Scholar]
- Curtis JR. 2010. Computed tomography shielding methods: a literature review. Radiol Technol 81: 428–436. [PubMed] [Google Scholar]
- Dere O. 2022. Breast glanduler dose and effectiveness of in-plane bishmut breast shield in routine pediatric female chest CT examination. Int J Curr Med Biol Sci 2: 179–184. [Google Scholar]
- Ehtiati A, Hejazi P, Bakhshandeh M, Arfaee AJ, Bolookat ER, Jadidi M, et al. 2021. The effect of contrast-enhanced computed tomography (CT) scans on the calculated dose of radiotherapy in a thorax phantom. Int J Cancer Manag 14(1):e84158. [Google Scholar]
- Einstein AJ, Elliston CD, Groves DW, Cheng B, Wolff SD, Pearson GD, et al. 2012. Effect of bismuth breast shielding on radiation dose and image quality in coronary CT angiography. J Nucl Cardiol 19: 100–108. [CrossRef] [PubMed] [Google Scholar]
- Feldle P, Grunz JP, Huflage H, Halt D, Schüle S, Sauer L, et al. 2023. Organ-based tube current modulation versus spectral shaping via tin prefiltration: what does bismuth breast shielding add in low-dose lung CT? Eur J Radiol 169: 111157. [CrossRef] [PubMed] [Google Scholar]
- Foley SJ, McEntee MF, Rainford LA. 2013. An evaluation of in-plane shields during thoracic CT. Radiat Prot Dosimetry 155: 439–450. [CrossRef] [PubMed] [Google Scholar]
- Hoffman DA, Lonstein JE, Morin MM, Visscher W, Harris III BS, Boice Jr, JD. 1989. Breast cancer in women with scoliosis exposed to multiple diagnostic X rays. J Natl Cancer Inst 81: 1307–1312. [CrossRef] [PubMed] [Google Scholar]
- Hopper KD. 2002. Orbital, thyroid, and breast superficial radiation shielding for patients undergoing diagnostic CT. Semin Ultrasound CT MR 23: 423–427. [CrossRef] [PubMed] [Google Scholar]
- Huggett J, Mukonoweshuro W, Loader R. 2013. A phantom-based evaluation of three commercially available patient organ shields for computed tomography X-ray examinations in diagnostic radiology. Radiat Prot Dosimetry 155: 161–168. [CrossRef] [PubMed] [Google Scholar]
- Ko CH, Lee SP, Hsieh YC, Lee YH, Yao MM, Chan WP. 2021. Bismuth breast-shield use in chest computed tomography for efficient dose reduction and sufficient image quality. Medicine (Baltimore) 100: e26277. [CrossRef] [PubMed] [Google Scholar]
- Lambert JW, Gould RG. 2016. Evaluation of a net dose-reducing organ-based tube current modulation technique: comparison with standard dose and bismuth-shielded acquisitions. AJR Am J Roentgenol 206: 1233–1240. [CrossRef] [PubMed] [Google Scholar]
- Lestari YM, Anam C, Sutanto H, Arifin Z, Alkian I, Suyudi I, et al. 2023. Evaluation of silicone rubber-lead shield’s effectiveness in protecting the breast during thoracic CT. Biomed Phys Eng Express 9. [PubMed] [Google Scholar]
- Liao YL, Lai NK, Tyan YS, Tsai HY. 2019. Bismuth shield affecting CT image quality and radiation dose in adjacent and distant zones relative to shielding surface: a phantom study. Biomed J 42: 343–351. [CrossRef] [PubMed] [Google Scholar]
- Mathews JD, Forsythe AV, Brady Z, Butler MW, Goergen SK, et al. 2013. Cancer risk in 680,000 people exposed to computed tomography scans in childhood or adolescence: data linkage study of 11 million Australians. Br Med J 346: f2360. [CrossRef] [Google Scholar]
- Mathieu KB, Cody DD. 2013. Partial arc beam filtration: a novel approach to reducing CT breast radiation dose. AJR Am J Roentgenol 200: 601–607. [CrossRef] [PubMed] [Google Scholar]
- Mehnati P, Arash M, Akhlaghi P. 2018. Bismuth-silicon and bismuth-polyurethane composite shields for breast protection in chest computed tomography examinations. J Med Phys 43: 61–65. [CrossRef] [PubMed] [Google Scholar]
- Mehnati P, Arash M, Zakerhamidi M, Ghavami M. 2019. Designing and construction of breast shields using silicone composite of Bismuth for chest CT. Int J Radiat Res 17: 491–496. [Google Scholar]
- Mehnati P, Malekzadeh R, Hussein HA, Obaid NH, Ebrahimiyan S, Sooteh MY, et al. 2023. Trade-off between breast dose and image quality using composite bismuth shields in computed tomography: a phantom study. J Med Imaging Radiat Sci 54: 145–152. [CrossRef] [PubMed] [Google Scholar]
- Mehnati P, Malekzadeh R, Sooteh MY. 2019. New Bismuth composite shield for radiation protection of breast during coronary CT angiography. Iran J Radiol 16: e84763. [CrossRef] [Google Scholar]
- Mendes M, Costa F, Figueira C, Madeira P, Teles P, Vaz P. 2015. Assessment of patient dose reduction by bismuth shielding in CT using measurements, GEANT4 and MCNPX simulations. Radiat Prot Dosimetry 165: 175–181. [CrossRef] [PubMed] [Google Scholar]
- Miglioretti DL, Johnson E, Williams A, Greenlee RT, Weinmann S, Solberg LI, et al. 2013. The use of computed tomography in pediatrics and the associated radiation exposure and estimated cancer risk. JAMA Pediatrics 167: 700–707. [CrossRef] [PubMed] [Google Scholar]
- Miller AB, Howe GR, Sherman GJ, Lindsay JP, Yaffe MJ, Dinner PJ, et al. 1989. Mortality from breast cancer after irradiation during fluoroscopic examinations in patients being treated for tuberculosis. N Engl J Med 321: 1285–1289. [CrossRef] [PubMed] [Google Scholar]
- Moonkum N, Pilapong C, Daowtak K, Tochaikul G. 2023. Evaluation of silicone rubber shielding material composites enriched with BaSO4 and Bi2O3 particles for radiation shielding properties. Mater Res Innov 27: 296–303. [CrossRef] [Google Scholar]
- Parker MS, Kelleher NM, Hoots JA, Chung JK, Fatouros PP, Benedict SH. 2008. Absorbed radiation dose of the female breast during diagnostic multidetector chest CT and dose reduction with a tungsten-antimony composite breast shield: preliminary results. Clin Radiol 63: 278–288. [CrossRef] [PubMed] [Google Scholar]
- Saba V, Keshtkar M. 2019. Targeted radiation energy modulation using Saba shielding reduces breast dose without degrading image quality during thoracic CT examinations. Phys Med 65: 238–246. [CrossRef] [PubMed] [Google Scholar]
- Schöckel L, Jost G, Seidensticker P, Lengsfeld P, Palkowitsch P, Pietsch H. 2020. Developments in X-ray contrast media and the potential impact on computed tomography. Invest Radiol 55: 592–597. [CrossRef] [PubMed] [Google Scholar]
- Tappouni R, Mathers B. 2013. Scan quality and entrance skin dose in thoracic CT: a comparison between bismuth breast shield and posteriorly centered partial CT scans. ISRN Radiol 2013: 457396. [CrossRef] [Google Scholar]
- Tochaikul G, Yokesahachart C, Daowtak K, Pilapong C, Moonkum N. 2024. Preparation and characterization of polylactic acid-based composite incorporating with BaSO4 for low radiation dose shielding. Polym Plast Technol Mater 63: 1733–1744. [Google Scholar]
- Vollmar SV, Kalender WA. 2008. Reduction of dose to the female breast in thoracic CT: a comparison of standard-protocol, bismuth-shielded, partial and tube-current-modulated CT examinations. Eur Radiol 18: 1674–1682. [CrossRef] [PubMed] [Google Scholar]
- Yilmaz MH, Albayram S, Yaşar D, Ozer H, Adaletli I, Selçuk D, et al. 2007. Female breast radiation exposure during thorax multidetector computed tomography and the effectiveness of bismuth breast shield to reduce breast radiation dose. J Comput Assist Tomogr 31: 138–142. [CrossRef] [PubMed] [Google Scholar]
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.