Open Access

Table 1

Exposure to our blackbody at various Z+Z0 distances: theoretical Eth and measured Em irradiance on [1,000; 2,500nm], and estimated by theory EIR,th and CatRayon EIR,CR5 and camera picture analysis EIR,pc on [780; 3,000nm]. At 800 celsius and 97 and 492 mm measurements failed. At 1,100 celsius and 97 mm the camera and the blackbody were a little misaligned. They were too misaligned at 1,200 celsius and 172 mm.

Black body Distance Z + Z0 λ=1,0002,500nmE(λ)λ λ=7803,000nmE(λ)λ
temperature theory measured theory by CR5 by camera
setting Z+Z0 Eth Em EIR,th EIR,CR5 EIR,pci
°C mm W/m2
800 97 209 −* 344 368 300
172 67 39 109 108 96
492 8 − * 13 13 12
900 97 381 341 589 579 527
172 122 101 187 185 175
492 15 12 23 22 22
1,000 97 644 571 944 928 811
172 207 174 299 198 220
492 25 20 37 36 32
1,100 97 1,023 918 1,433 1,410 863**
172 328 292 455 452 343
492 40 33 55 56 47
1,200 97 1,542 1,348 2,083 2,050 1,886
172 495 440 661 657 −***
492 61 49 81 81 73
1,300 97 2,231 2,089 2,922 2,876 2,711
172 716 692 927 922 846
492 88 74 113 112 102

Les statistiques affichées correspondent au cumul d'une part des vues des résumés de l'article et d'autre part des vues et téléchargements de l'article plein-texte (PDF, Full-HTML, ePub... selon les formats disponibles) sur la platefome Vision4Press.

Les statistiques sont disponibles avec un délai de 48 à 96 heures et sont mises à jour quotidiennement en semaine.

Le chargement des statistiques peut être long.