Occupational eye lens dose among nuclear medicine workers in a tertiary hospital in Saudi Arabia
1
Department of Radiology, King Abdulaziz University Hospital, King Abdulaziz University, Jeddah, Saudi Arabia
2
Department of Radiology, Faculty of Medicine, King Abdulaziz University, Jeddah, Saudi Arabia
3
Ibn Sina National College for Medical Studies, Jeddah, Saudi Arabia
* Corresponding author: Ranim.nasr1995@gmail.com; rnasr@kau.edu.sa
Received:
2
October
2023
Accepted:
27
May
2024
Background: Exposure to ionizing radiation remains a major concern in nuclear medicine, especially given the possible health risks posed to medical personnel. Additionally, since the occupational eye dose limit was lowered in 2011 to an equivalent dose of 20 mSv/yr, new implications have extended to roles within nuclear medicine units. The goal of this investigation was to determine the current occupational radiation eye doses for nuclear medicine employees. Methods: A 5 yr retrospective assessment was performed on staff members involved in all nuclear medicine imaging from different categories. Optically Stimulated Luminescence (OSL) badges were used to measure occupational dose. The H-lens values were calculated for each staff member during this period. Results: Significant differences were observed between individual staff members in terms of H-lens values. They were significantly higher among hot lab technicians than among NIC (p < 0.001) and NM (p < 0.0001) technicians. Conclusions: Although none of the participants exceeded the eye dose limit for ionizing radiation exposure, there was significant variation in exposure across various roles and expertise. The annual average eye dose ranged from 0.2 mSv to 2.9 mSv, which is within the advised dose limit.
Key words: eye lens dose / nuclear medicine / radiation protection / occupational doses
© R.Y. Nasr et al., Published by EDP Sciences, 2024
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Les statistiques affichées correspondent au cumul d'une part des vues des résumés de l'article et d'autre part des vues et téléchargements de l'article plein-texte (PDF, Full-HTML, ePub... selon les formats disponibles) sur la platefome Vision4Press.
Les statistiques sont disponibles avec un délai de 48 à 96 heures et sont mises à jour quotidiennement en semaine.
Le chargement des statistiques peut être long.