Free Access
Table 1
Overview on studies on the determination of radon in waterworks.
Country/region | No. of waterworks | Results published | 222Rn in air methodology | 222Rn in air | Dose calculation based on | F applied | Occupational annual effective dose | Reference |
---|---|---|---|---|---|---|---|---|
Poland/Upper Silesia | 9 | Annual effective dose | SSNTD for local exposure (CR-39 type; 3–6 months) | Passive local measurements, estimated working time of the staff | 0.4 | 1 of 9 > 1 mSv y−1⁎ | Chmielewska et al., 2014 | |
Austria/whole country except Upper Austria | 21 | 222Rn in air and water, 220Rn in air, annual effective dose | SSNTD for local exposure (CR-39 type; 3 months and 2 weeks), ionizing chamber | Max. 38000 Bq m−3 | Passive local measurements, individual residence times and the natural geogenic background | 0.4 | 0.03–5.31 mSv y−1, 0.92 mSv y−1 (mean), 0.49 mSv y−1 (median) |
Stietka et al., 2014 |
Germany/Baden-Württemberg | 117 | 222Rn in air, annual effective dose | SSNTD for local (2 weeks) and personal exposure (3 months), ionizing chamber working level meter | 49% < 1 kBq m−3 <29% < 5 kBq m−3 <14% < 10 kBq m−3 <8%⁎⁎⁎ |
Passive personal measurements, average residence time of 4.68 h d−1 | 0.4 | 17 of 275 > 6 mSv y−1 >25 of 275 > 3 mSv y−1⁎⁎ |
Nagels et al., 2009 |
Austria/Upper Austria | 45 | 222Rn in air | Electret ion chamber, ionizing chamber, silicon detector | 55% < 1000 Bq m−3, 91% < 5000 Bq m−3⁎⁎⁎ | Passive local measurements, individual exposure times 43% < 100 h y−1, 95% < 1000 h y−1⁎⁎⁎⁎ | 3 of 45 > 6 mSv y−1⁎ | Ringer et al., 2008 | |
Sweden/Falun, Malmoe, Vaxjoe, Umea, Oerebro | 60 | 222Rn in air, annual effective dose | SSNTD for local exposure (1–3 months) | 49 of 60 > 1 kBq m−3, 21 of 60 > 4 kBq m−3⁎ |
Passive local measurements, time spent of the employees | up to 20 mSv y−1 | Marinko et al., 2004 | |
Germany/Bavaria | ∼500 | 222Rn in air and water, annual effective dose | SSNTD for local (CR-39 type; 2 weeks) and SSNTD for personal exposure (CR-39 type; 2 months) | 54% > 1 kBq m−3, 30% > 3 kBq m−3 ⁎⁎⁎ |
Passive personal measurements for normal activities and separate personal measurements for cleaning works | 0.4 | 12% > 6 mSv y−1, 5% > 20 mSv y−1⁎⁎ | Trautmannsheimer et al., 2003 |
Slovenia/whole country | 10 | 222Rn in air and water, 226Ra in water, annual effective dose | Air alpha scintillation cells (instantaneous), SSNTD for local exposure (1 month) | 40–2600 Bq m−3 | Passive local measurements, individual exposure times provided by the management (from 8 to 2602 h y−1) | 0.4 | 0–3.0 mSv y−1 | Vaupotic, 2002 |
Germany/Hesse | 22 | 222Rn in air, 222Rn in water, annual effective dose | Passive devices for local and personal exposure, active devices for local exposure | 0–20000 Bq m−3 | Active local measurements with worst case residence times for selected waterworks; passive personal measurements separated for normal and cleaning activities | Usual works < 6 mSv y−1, additionally 0.06–0.3 mSv per tank cleaning |
Hingmann et al., 2001 | |
USA/Iowa | 31 | 222Rn in air | SSNTD for local exposure (1 year), continuous 222Rn air monitor (3–6 days) | 15–4921 Bq m−3, 18 of 31 < 148 Bq m−3 <12 of 31 <740 Bq m−3 < 1 of 31⁎ |
Active local measurements linked to actual time spent for selected waterworks; passive local measurements with average time spent based on questionnaire | 1.0 | 0.005–0.65 WLM y−1 | Fisher et al., 1996 |
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.