Issue |
Radioprotection
Volume 53, Number 4, October-December 2018
|
|
---|---|---|
Page(s) | 279 - 286 | |
DOI | https://doi.org/10.1051/radiopro/2018033 | |
Published online | 10 December 2018 |
Article
Radiation exposure of very-low-birth-weight infants in neonatal intensive care units in Korea
1
Department of Pediatrics, Soonchunhyang University Bucheon Hospital, Soonchunhyang University College of Medicine,
170 Jomaru-ro,
Bucheon
14584, Republic of Korea
2
Departments of Radiology, Soonchunhyang University Bucheon Hospital, Soonchunhyang University College of Medicine,
170 Jomaru-ro,
Bucheon
14584, Republic of Korea
* Corresponding author: sungshin1201@gmail.com
Received:
26
April
2018
Accepted:
14
September
2018
To our knowledge, no study has reported the radiation doses of neonates admitted to neonatal intensive care units (NICUs) in Korea. Therefore, we evaluated the radiation frequency and dose of radiation performed in NICUs using mobile X-ray machines. We retrospectively analyzed the number of radiographs and doses among 290 very low-birth-weight infants (VLBWIs) admitted at our hospital between 2011 and 2016. We compared X-ray frequencies and radiation doses according to clinical characteristics and morbidities. The entrance surface doses (ESDs) were calculated using the non-dosimeter dosimetry formula. The median number of radiographs per infant was 26, and about 25% neonates had over 50 radiographs. The number of radiographs taken was higher for infants with low-birth-weight (LBW), respiratory distress syndrome, bronchopulmonary dysplasia, and longer central venous catheterization duration (p < 0.001 for all). The cumulative ESD was 0.18 to 9.89 mGy, and the ESD per radiograph was 0.049 to 0.069 mGy. The LBW and the more severe the neonates’ condition, the greater was the radiation exposure. It is difficult to reduce the number of radiographic examinations, but the quality of examinations must be improved without compromising patient care. Additional studies are needed to minimize the cumulative exposure dose and achieve optimal image quality.
Key words: neonatal intensive care units / radiation dose / low-birth-weight infant
© EDP Sciences 2018
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.