  • Bardiès M., Pihet P. (2000) Dosimetry and microdosimetry of targeted radiotherapy, Curr. Pharm. Des. 6, 1469-1502. [Google Scholar]
  • Briesmeister J.F. (1997) MCNPTM - A general Monte Carlo N-particle transport code, version 4B. Report LA-12625-M. Los Alamos, NM: Los Alamos National Laboratory. [Google Scholar]
  • Chiavassa S., Lemosquet A., Aubineau-Lanièce I., de Carlan L., Clairand I., Ferrer L., Bardiès M., Franck D., Zankl M. (2005) Dosimetric Comparison of Monte Carlo codes (EGS4, MCNP, MCNPX) Considering External And Internal Exposures Of The Zubal Phantom To Electron And Photon Sources, Radiat. Prot. Dosim. 116, 631-635. [CrossRef] [Google Scholar]
  • Chiavassa S., Aubineau-Lanièce I., Bitar A., Barbet J., Franck D., Jourdain J.R., Bardiès M. (2006) Validation of a personalized dosimetric evaluation tool (OEDIPE) for targeted radiotherapy nased on the Monte Carlo MCNPX code, Phys. Med. Biol. 51, 601-616. [CrossRef] [PubMed] [Google Scholar]
  • Halbleib J.A., Kensek R.P., Mehlorn T.A., Valdez G.D., Seltzer S.M., Berger M.J. (1992) ITS version 3,0 Integrated TIGER Series of coupled electron/photon Monte Carlo transport codes, SAND91-1634. [Google Scholar]
  • Hendricks J.S. (2004) MCNPX, Version 2.5e, LA-UR-04-0569. [Google Scholar]
  • Hubbell J.H., Veigele W.J., Briggs E.A., Brown R.T., Cromer D.T., Howerton R.J. (1975) Atomic form factors, incoherent scaterring functions, and photon scattering cross sections, J. Phys. Chem. Ref. Data 4, 471. [NASA ADS] [CrossRef] [Google Scholar]
  • Hughes H.G., Prael R.E., Little R.C. (1997) MCNPX the LAHET/MCNP Code Merger, XTM-RN (U), 97-012 report. [Google Scholar]
  • ICRP Publication 38 (1983) Radionuclide Transformations: Energy and Intensity of Emissions, Ann. ICRP 11-13. [Google Scholar]
  • Jarnet D., Denizot B., Bitar A., Bardiès M., Lisbona A., Jallet P. (2004) New thermoluminescent dosimeters (TLD) : optimization and characterization of TLD threads sterilizable by autoclave, Phys. Med. Biol. 49, 1803-1815. [CrossRef] [PubMed] [Google Scholar]
  • Loevinger R., Budinger T., Watson E. (1991) MIRD primer for absorbed dose calculations. Society of Nuclear Medicine, New York. [Google Scholar]
  • Yoriyaz H., Stabin M.G., Dos Santos A. (2001) Monte Carlo MCNP-4B-based absorbed distribution estimates for patient-specific dosimetry, J. Nucl. Med. 42, 662-669. [PubMed] [Google Scholar]