Numéro |
Radioprotection
Volume 58, Numéro 3, July - September 2023
|
|
---|---|---|
Page(s) | 197 - 204 | |
DOI | https://doi.org/10.1051/radiopro/2023008 | |
Publié en ligne | 14 septembre 2023 |
Article
Dose assessment based on short-ranged computer simulation in a radioactive release event
1
Nuclear Engineering Graduate Program, Military Institute of Engineering, Rio de Janeiro, Brazil
2
Defense Engineering Graduate Program, Military Institute of Engineering, Rio de Janeiro, Brazil
3
Institute for Chemical, Biological, Radiological and Nuclear Defense (IDQBRN), Rio de Janeiro, Brazil
4
FAAP, Faculty of Economics, Graduate Program, São Paulo, Brazil
* Corresponding author: andradepged@ime.mil.br
Received:
27
October
2022
Accepted:
27
February
2023
This study describes the computational modeling of the atmospheric dispersion of radionuclides resulting from a hypothetical nuclear accident involving an off-site release of the inventory of a Small Modular Reactor (SMR). The inventory released was simulated with the aid of the SCALE software, considering 2 years of continuous operation. The radionuclide Cs-137 was selected due to its abilities to cause environmental damage. A simulation of the atmospheric dispersion of the radionuclide was performed using the codes HotSpot (analytical) and ANSYS (numerical). The distribution of concentrations and consequent equivalent total effective doses (TEDE) were estimated as a function of the distance from the point of release and the local atmospheric stability conditions. In the study, a hybrid computer simulation refers to the simultaneous application of the analytical and numerical models of the nuclear event. The results from the simulated conditions agree with the environmental Cs-137 concentration values, regardless of whether those values are from a numerical or analytical model. However, there is a disagreement about the location and distribution of these concentrations. It was also verified that the average percentage error of the results obtained in the two simulations was around 5%, considering the evaluation between 400 and 1500 m from the origin of the dispersion. For smaller distances in relation to the release point, the analytical and numerical models produce solutions that, although divergent, were shown to be complementary. The relevance of this investigation shows the importance of the convergence of isolated computing platforms in order to support decision-making.
Key words: computing modeling / radiation dose / simulation / radiation release
© SFRP, 2023
Les statistiques affichées correspondent au cumul d'une part des vues des résumés de l'article et d'autre part des vues et téléchargements de l'article plein-texte (PDF, Full-HTML, ePub... selon les formats disponibles) sur la platefome Vision4Press.
Les statistiques sont disponibles avec un délai de 48 à 96 heures et sont mises à jour quotidiennement en semaine.
Le chargement des statistiques peut être long.