Free Access
Issue |
Radioprotection
Volume 51, Number 1, January-March 2016
|
|
---|---|---|
Page(s) | 59 - 63 | |
DOI | https://doi.org/10.1051/radiopro/2015030 | |
Published online | 28 March 2016 |
- Ay M.R. et al. (2005) MCNP4C-based Monte Carlo simulator for fan and cone-beam X-ray CT: development and experimental validation, Biomedizinische Technik 50, 360-361. [Google Scholar]
- Breustedt B. et al. (2010) Monte Carlo calibration of whole-body counters with NaI(Tl) detectors in stretcher geometry, Radiat. Prot. Dosim. 139 (4), 510-518. [CrossRef] [Google Scholar]
- Broggio D. et al. (2012) Monte Carlo modelling for the in vivo lung monitoring of enriched uranium: Results of an international comparison, Radiat. Meas. 47, 492-500. [CrossRef] [Google Scholar]
- Briesmeister F. (2000) MCNP–A general Monte Carlo N-particle transport code version 4C, Los Alamos National Laboratory Report LA-13709-M. [Google Scholar]
- Carinou, E., et al. (2007) The calculation of a size correction factor for a whole-body counter, Nucl. Instrum. Meth. Phys. Res. A 580, 197-200. [CrossRef] [Google Scholar]
- ICRP Publication 89 (2002) Basic Anatomical and Physiological Data for Use in Radiological Protection: Reference Values, Ann. ICRP 32 (3-4). [CrossRef] [Google Scholar]
- Joana B. et al. (2012) Monte Carlo Simulation of the Movement and Detection Efficiency of a Whole-body Counting System Using a BOMAB Phantom, Radiat. Prot. Dosim. 148 (4), 403-413. [CrossRef] [Google Scholar]
- Kramer G.H. (2006) The sliced BOMAB phantom: a new variant for intercomparison, Health Phys. 90, 161-166. [CrossRef] [PubMed] [Google Scholar]
- Huang J.-W. et al. (2014) Efficiency calibration for a NaI scintillation detector based on Monte Carlo process and preliminary measurements of bremsstrahlung, Acta Physica Sinica 63, 180702. [Google Scholar]
- Nogueira P. et al. (2010) Monte Carlo simulation of the full energy peak efficiency of a WBC, Appl. Radiat. Isotopes 68, 184-189. [CrossRef] [Google Scholar]
- Peter S. et al. (2014) Combining Monte Carlo methods with coherent wave optics for the simulation of phase-sensitive X-ray imaging, J. Synchrotron Radiat. 21, 613-622. [CrossRef] [PubMed] [Google Scholar]
- Snyder W.S. et al. (1978) Estimates of absorbed fractions for monoenergetic photon source uniformly distributed in various organs of a heterogeneous phantom. The Society of Nuclear Medicine; Medical Internal Radiation Dose Committee (MIRD), New York. Pamphlet No. 5. [Google Scholar]
- Uenoa K. et al. (2014) On-line 60Co monitor for reactor recirculation system piping in primary containment vessel during reactor operation, Nucl. Eng. Design 278, 352-359. [CrossRef] [Google Scholar]
- Wang J. et al. (1998) Data of Anatomical Physiological and Metabolizing Characteristics for Chinese Referrence Man. China Atomic Energy Press, Beijing (in Chinese). [Google Scholar]
- Zhang J. et al. (2014) Monte Carlo Simulation and Analysis of γ-Rays for the Important Elements of Lunar Surface, Nucl. Phys. Rev. 31, 112-117. [Google Scholar]
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.