Table 3
Equivalent dose rate coefficients for pure beta emitters and radionuclides with maximum beta energy above 1 MeV.
| Radionuclide | Equivalent dose rate coefficient (μSv/h/GBq at 1 m) | Reference |
|---|---|---|
| phosphorus-32 | 15.2 | n.c. |
| strontium-89 | 35.2 | n.c. |
| yttrium-90: Liquid form SIR-sphere® Therasphere® |
20.3 4 2 |
(Aubert et al., 2002) (McCann et al., 2012) (McCann et al., 2012) |
| erbium-169 | 8.3 | n.c. |
| rhenium-186 | 28.1 | n.c. |
n.c.: not concerned. The equivalent dose rate coefficients for these radionuclides were derived from the coefficient for yttrium-90 (liquid form, i.e., 20.3 μSv/h/GBq at 1 m as indicated above), taken as a reference. The calculation assumed proportionality between the maximum beta energy of the radionuclide and that of yttrium-90, while also accounting for the beta emission intensity (%) and the ratio 21/7.9 corresponding to the ratio of the effective atomic numbers of bone to soft tissue.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.