EDP Sciences Journals List
Free access article

Issue Radioprotection
Volume 43, Number 5, 2008
36th annual meeting of the European Radiation Research Society
Article Number 018
Number of page(s) 1
Section Poster Presentation - Biological Dosimetry
DOI 10.1051/radiopro:2008636
Published online 03 September 2008

Radioprotection 2008, Vol. 43, n° 5
DOI: 10.1051/radiopro:2008636

Automatic detection of dicentrics chromosomes in biodosimetry

A. Vaurijoux1, G. Gruel1, F. Pouzoulet1, E. Grégoire1, C. Martin1, S. Roch-Lefèvre1, P. Voisin1 and L. Roy2

1  IRSN/DRPH/SRBE/LDB, BP 17, 92262 Fontenay-aux-Roses, France, Metropolitan
2  IRSN, DRPH/SRBE, LRTOX, BP n°17, 92262 Fontenay aux roses, France


Published online: 4 September 2008

Abstract
In case of large scale accidental overexposure to ionizing radiation, a rapid triage of the population exposed is needed first, followed by an accurate dose estimation for each individual. Currently, these two steps are performed by scoring unstable chromosomal aberrations (dicentrics, rings and fragments) in peripheral blood lymphocytes after Giemsa staining. For the triage step, only 50 metaphases are currently manually analysed. This is rapid but not accurate and may introduce false negative dose classification. For the second step, 500 metaphases are currently manually analysed. This is very accurate but very long. To improve the method, we have studied the automatic dicentrics detection by Metafer 4 software (MetaSystems) on accidental overexposure victims of the Dakar accident (Africa). The study has been performed firstly by the manual scoring of dicentrics on 50 metaphases (50 MS) used for a population triage, secondly by the manual scoring of dicentrics on 500 metaphases (standard approach; 500 MS) and thirdly by the automatic scoring of dicentrics (ADS). The comparison between dose classification obtained by 50MS and obtained by 500MS methods shows 54.2% (32 on 59 individuals) correlation however there is 45.8% (27 on 59 individuals) of underestimation. Moreover, comparisons of dose classification between the results obtained by ADS and 500MS show 95.7% (44 on 46 individuals) of correlation and 4.3% (2 on 46 individuals) of underestimation. In addition, the mean doses obtained by ADS method are near to the mean doses obtained by 500MS. To conclude, ADS method is faster and more accurate than the manual scoring of 50 cells and could be used in case of triage. In addition, ADS method could also be used instead of 500MS in case of individual dose estimation as it is as accurate and much faster.


Key words: automation -- dicentrics chromosomes -- triage -- accidental overexposure


© EDP Sciences 2008


What is OpenURL?

The OpenURL standard is a protocol for transmission of metadata describing the resource that you wish to access. An OpenURL link contains article metadata and directs it to the OpenURL server of your choice. The OpenURL server can provide access to the resource and also offer complementary services (specific search engine, export of references...). The OpenURL link can be generated by different means.
  • If your librarian has set up your subscription with an OpenURL resolver, OpenURL links appear automatically on the abstract pages.
  • You can define your own OpenURL resolver with your EDPS Account. In this case your choice will be given priority over that of your library.
  • You can use an add-on for your browser (Firefox or I.E.) to display OpenURL links on a page (see http://www.openly.com/openurlref/). You should disable this module if you wish to use the OpenURL server that you or your library have defined.